Exaggerated radial oscillations can result in permanent defects in the microbubble shell, which results in rapid loss of gas from the microbubbles. Finally, abrupt fragmentation of microbubbles have been visualized with only a single high energy ultrasound pulse.2),17),18) Microbubble destruction results in the generation of strong harmonic signals which can be used to separate microbubbles from tissue noise, but to detect Inhibitors,research,lifescience,medical microbubbles which are attached to the endothelial surface, only a single pulse of high energy ultrasound could be used since all
the microbubbles within the sound field would subsequently be eliminated. Therefore, although such an imaging technique could be used for in vitro proof-of-principle studies and animal experiments, it would not be feasible in a clinical setting. When the mechanical index of ultrasound is reduced Inhibitors,research,lifescience,medical to very low levels (-0.1), and the frequency of ultrasound approximates the resonant frequency of the microbubble,19),20) non-linear microbubble oscillation can be induced during insonation without microbubble destruction, which still
results in the production of unique harmonic signals. Tissue backscatter signals, on the other hand, contain very low amplitude harmonic signals Inhibitors,research,lifescience,medical at such a low mechanical index, making the separation of microbubble signals from tissue noise possible. Because imaging is being performed at a low power that prevents microbubble destruction – high frame rates and continuous imaging Inhibitors,research,lifescience,medical can be used which offers multiple advantages for targeted imaging. For example, a user could localize the correct scanning plane without destroying the targeted microbubbles and degrading the signal. Targeted microbubbles attached to a cell surface, and even microbubbles which have been phagocytosed into leukocytes
continue to remain acoustically Inhibitors,research,lifescience,medical active.21-23) In order to minimize interference from freely circulating microbubbles, targeted microbubbles which are not attached to the endothelial cell surface are given time to clear from the circulation before imaging is performed. In general, a delay of approximately 10 min is adequate to allow free microbubbles to be cleared by the reticuloendothelial system, at which time imaging should detect only targeted Non-specific serine/threonine protein kinase agent retained in diseased tissue.15) Applications of Molecular Imaging Inflammatory imaging 2D echocardiography can be used to evaluate wall thickening, which is closely dependent on buy IOX2 resting myocardial blood flow (MBF). Because myocardial contractility is a major determinant of myocardial oxygen consumption, reductions in resting MBF are followed within seconds by the development of a wall thickening abnormality.24) Furthermore, ischemic myocardial segments with low resting flow will demonstrate resting perfusion defects.